Current sense resistors are widely adopted in switching power supplies, motor drives and battery management systems for current sampling and closed-loop control. Many design errors come from simply selecting resistance value according to the target voltage signal, ignoring thermal drift, power derating and parasitic inductance. These factors will introduce sampling deviation and affect the stability of current loop control.
| Resistor Type | Temperature Coefficient | Parasitic Inductance | Typical Application |
| Metal Alloy Resistor | Low | Low | High-precision high-current sampling |
| Thick Film Chip Resistor | Medium | Medium | General low-current detection |
| Thin Film Chip Resistor | Very Low | Low | Small signal precision sampling |
| Wirewound Resistor | Medium | High | Low-frequency high-power detection |
Self-heating effect: power dissipation raises temperature and shifts resistance value
Parasitic inductance: voltage spike generated under high di/dt interferes with sampling signal
Kelvin connection missing: voltage drop on power copper leads is counted into sampling result
Ambient temperature variation: temperature coefficient brings long-term drift of sampling baseline
Underestimated current signal will cause overcurrent protection failure and risk device burnout. Overestimated sampling value limits the actual output capacity of the power supply. Drifted current feedback also triggers unstable loop oscillation, output fluctuation and inconsistent performance between product batches.
Resistance value should be determined by signal amplitude and ADC input range. Rated power must be derated sufficiently, generally below 50% of the rated power under continuous operation. For high-frequency switching loops, low-inductance alloy resistors are preferred to reduce inductive voltage noise.
Separate power path and sense path with Kelvin routing. The two sensing traces should directly connect to the resistor sensing terminals and run to the amplifier input. Avoid placing sense traces near high dv/dt power lines. Thermal isolation is recommended to reduce heat transfer from surrounding power devices to the sampling resistor.